    Online UPS LF
    CDP SERIES
    CDP SERIES

    CDP SERIES

    1P/1P

    Tower form

    Online / Low Frequency












     

    Brief Introduction

     

    CHADI CDP series are 1 phase in 1 phase out UPS. Their capacity range from 7.5KVA to 30KVA. These series have applied full digital control technology based on DSP (digitalized signal processor). High efficiency transformation endures high power current and high voltage with an extremely low consumption. The machine can run self-diagnose, and with standard RS232 for SNMP or RS485 cards, they are conveniently managed by central monitoring and remote monitoring. The latest Redundancy Parallel Array technology is available with these series. RPA function can operate on up 32 units.

     

    Product Features

     

    • Applying full digital control technology based on DSP            
    • The shift time between Invertion and bypass is less than 1 millisecond.                                          
    • AC start (cold start), convenient to operate           
    • Auto re-start function           
    • Complete protection and alarm functions, MCU is monitoring all circuits and detecting bugs during the long run           
    • Extremely wide input voltage range           
    • Self-diagnose function           
    • Isolated output transformer islotated the electricity shock from various loads           
    • Most advanced RPA functions allow up to 32 units of machines to be working in the parallel array           

     

    Technical Data Sheet

     

    MODELCDP-2K/PCDP-3K/PCDP-5K/PCD-6K/PCDP-7.5K/PCDP-10K/PCDP-15K/PCDP-20K/LCD-30K/LCDP-40K/L
    Rated Power1.6KW2.4KKW4KW4.8KW6KW8KW12KW16KW24KW32KW
    INPUT
    Rated Voltagesingle phase 220V±25% or 110V±25%
    Frequency50 Hz/60Hz ±5%(optional ±10%)
    Power Factor3KVA4.5KVA7.5KVA9KVA11.3KVA15KVA22.5KVA30KVA45KVA60KVA
    OUTPUT
    Rated Voltagesingle phases 220V±1%
    Frequency50/60Hz±0.5% (inverted tense)
    Waveform DistortionPure sine wave, distortion 2.5 as with linear loads, while 3 as with non-linear loads (when full load)
    Imbalance of parallelcurrent <5%
    Overload CapacityOver load 120% can last 10 minutes, over load 150% can last 20 seconds
    Wave Crest Coefficient5:1(full loading)
    BATTERY
    Rated Voltage192VDC 
    Battery Nos.12Vdcx32 nos.
    Battery Voltage12 Vdc (15-20 nos adjustable)
    Back-up TimeExtra batteryback-up time is determined by battery capacity
    Back-up Time for battery built-in typeBattery built-in type, use 12V/7AH VRMF lead acid battery
    13 min8 min6 min5 minN/A
    System
    Transfer TimeAC←→battery 0 msInverter←→bypass 4 ms
    Ingress ProtectionIP20
    Conversion Efficiency≥85%(full loading)
    Noise50db(1 meter)53db(1meter)55db(1meter)
    ENVIRONMENT
    Temperature0℃~45℃
    Humidity0~93% RH,non-condensing
    Altitude1500m
    Size
    W×D×Hmm260×620×625410*752*941
    Weight
    N. Weight (kg)75/4580/5095/60100/658595127142210240
    G. Weight (kg)85/5590/60105/70110/75115125170220265280