Hotline:0086-133-9278-8695
Email:biz@ups-chadi.com
Website:www.ups-chadi.com
Skype: speedi-chan
Viber/Whatsapp:0086-15818062900
Brief Introduction
CHADI CDP series are 1 phase in 1 phase out UPS. Their capacity range from 7.5KVA to 30KVA. These series have applied full digital control technology based on DSP (digitalized signal processor). High efficiency transformation endures high power current and high voltage with an extremely low consumption. The machine can run self-diagnose, and with standard RS232 for SNMP or RS485 cards, they are conveniently managed by central monitoring and remote monitoring. The latest Redundancy Parallel Array technology is available with these series. RPA function can operate on up 32 units.
Product Features
• Applying full digital control technology based on DSP
• The shift time between Invertion and bypass is less than 1 millisecond.
• AC start (cold start), convenient to operate
• Auto re-start function
• Complete protection and alarm functions, MCU is monitoring all circuits and detecting bugs during the long run
• Extremely wide input voltage range
• Self-diagnose function
• Isolated output transformer islotated the electricity shock from various loads
• Most advanced RPA functions allow up to 32 units of machines to be working in the parallel array
Technical Data Sheet
MODEL | CDP-2K/P | CDP-3K/P | CDP-5K/P | CD-6K/P | CDP-7.5K/P | CDP-10K/P | CDP-15K/P | CDP-20K/L | CD-30K/L | CDP-40K/L | |
Rated Power | 1.6KW | 2.4KKW | 4KW | 4.8KW | 6KW | 8KW | 12KW | 16KW | 24KW | 32KW | |
INPUT | |||||||||||
Rated Voltage | single phase 220V±25% or 110V±25% | ||||||||||
Frequency | 50 Hz/60Hz ±5%(optional ±10%) | ||||||||||
Power Factor | 3KVA | 4.5KVA | 7.5KVA | 9KVA | 11.3KVA | 15KVA | 22.5KVA | 30KVA | 45KVA | 60KVA | |
OUTPUT | |||||||||||
Rated Voltage | single phases 220V±1% | ||||||||||
Frequency | 50/60Hz±0.5% (inverted tense) | ||||||||||
Waveform Distortion | Pure sine wave, distortion ≤2.5 as with linear loads, while ≤3 as with non-linear loads (when full load) | ||||||||||
Imbalance of parallel | current <5% | ||||||||||
Overload Capacity | Over load 120% can last 10 minutes, over load 150% can last 20 seconds | ||||||||||
Wave Crest Coefficient | 5:1(full loading) | ||||||||||
BATTERY | |||||||||||
Rated Voltage | 192VDC | ||||||||||
Battery Nos. | 12Vdcx32 nos. | ||||||||||
Battery Voltage | 12 Vdc (15-20 nos adjustable) | ||||||||||
Back-up Time | Extra battery(back-up time is determined by battery capacity) | ||||||||||
Back-up Time for battery built-in type | Battery built-in type, use 12V/7AH VRMF lead acid battery | ||||||||||
13 min | 8 min | 6 min | 5 min | N/A | |||||||
System | |||||||||||
Transfer Time | AC←→battery 0 ms;Inverter←→bypass < 4 ms | ||||||||||
Ingress Protection | IP20 | ||||||||||
Conversion Efficiency | ≥85%(full loading) | ||||||||||
Noise | 50db(1 meter) | 53db(1meter) | 55db(1meter) | ||||||||
ENVIRONMENT | |||||||||||
Temperature | 0℃~45℃ | ||||||||||
Humidity | 0~93% RH,non-condensing | ||||||||||
Altitude | <1500m | ||||||||||
Size | |||||||||||
W×D×H(mm) | 260×620×625 | 410*752*941 | |||||||||
Weight | |||||||||||
N. Weight (kg) | 75/45 | 80/50 | 95/60 | 100/65 | 85 | 95 | 127 | 142 | 210 | 240 | |